Reimer Duran posted an update 1 week, 6 days ago
0). (3) LLIF + 4-screw MPF and supplemental interspinous process fixation range-of-motion reduction was comparable to LLIF + bilateral pedicle screw fixation in all directions (
≥ .6).
LLIF with 4-screw MPF may provide inherent advantages over traditional 2-screw plating modalities. Furthermore, when coupled with interspinous process fixation, LLIF with MPF is a stable circumferential construct that provides biomechanical utility in all principal motions.
LLIF with 4-screw MPF may provide inherent advantages over traditional 2-screw plating modalities. Furthermore, when coupled with interspinous process fixation, LLIF with MPF is a stable circumferential construct that provides biomechanical utility in all principal motions.
Retrospective cohort study.
The aim of this study is to identify predictive factors associated with failure of nonoperative management of spinal epidural abscess (SEA).
Between January 2007 and January 2017, there were 97 patients 18 years or older treated for SEA at a tertiary referral center. Of these, 58 were initially managed nonoperatively. find more Details on presenting complaint, laboratory parameters, radiographic evaluation, demographics, comorbidities, and neurologic status (Frankel grades A-E) were collected. Success of treatment was defined as eradication of infection with no requirement for further antimicrobial therapy. Diagnosis of SEA was made via evaluation of imaging and intraoperative findings. Patients with repeat presentation of SEA, children, and those who were transferred for immediate surgical decompression were excluded.
Fifty-eight patients initially treated nonoperatively were included. Of these, 21 failed nonoperative management and required surgical intervention. The mean age was 60 years, 66% male, and 19% of Maori ethnicity. Abscess location was predominantly dorsal, and in the lumbar region (53%). Multivariate analysis identified Maori ethnicity, multifocal sepsis, and elevated white cell count as predictors of failure of nonoperative management. With 1 predictor the risk of failure was 44%. In the presence of 2 predictive variables, failure rate increased to 60%, and if all 3 variables were present, patients had a 75% risk of failure.
Thirty-six percent of patients treated nonoperatively failed nonoperative management-the failure rate was significantly increased in patients with multifocal sepsis, in patients with elevated white cell count, and in patients of Maori ethnicity.
Thirty-six percent of patients treated nonoperatively failed nonoperative management-the failure rate was significantly increased in patients with multifocal sepsis, in patients with elevated white cell count, and in patients of Maori ethnicity.
Systematic review.
To assess the methodological quality of systematic reviews and meta-analyses in spine surgery over the past 2 decades.
We conducted independent and in duplicate systematic review of the published systematic reviews and meta-analyses between 2000 and 2019 from PubMed Central and Cochrane Database pertaining to spine surgery involving surgical intervention. We searched bibliographies to identify additional relevant studies. Methodological quality was evaluated with AMSTAR score and graded with AMSTAR 2 criteria.
A total of 96 reviews met the eligibility criteria, with mean AMSTAR score of 7.51 (SD = 1.98). Based on AMSTAR 2 criteria, 13.5% (n = 13) and 18.7% (n = 18) of the studies had high and moderate level of confidence of results, respectively, without any critical flaws. A total of 29.1% (n = 28) of the studies had at least 1 critical flaw and 38.5% (n = 37) of the studies had more than 1 critical flaw, so that their results have low and critically low confidence, respectively. Fust be taken to adhere to methodological quality by following PRISMA and AMSTAR guidelines to attain higher standards of evidence in published literature.
Biomechanical investigation.
To compare the biomechanical performance of nitinol memory metal rods and titanium rods when used as posterior spinal instrumentation in a synthetic model.
Biomechanical testing was performed using ultra-high-molecular-weight polyethylene blocks. Nineteen spinal constructs were created to allow comparison of 5.5-mm nitinol rods with 5.5-mm titanium rods. Static compression and rotational testing were performed on an Instron 8874 and Instron 4202 at 37°C to simulate body temperature.
The average titanium construct stiffness under static compression or bending was 47.2 ± 9.1 N/mm while nitinol’s stiffness averaged 48.9 ± 12.4 N/mm (
= .83). During axial rotation testing, the nitinol rod system showed no torsional stiffness difference from the titanium system 0.95 ± 0.03 Nm/deg versus 0.96 ± 0.17 Nm/deg, respectively (
= 0.91). There was a statistically significant difference between the average torsional yield point for the titanium constructs (14.4 ± 1.6 Nm/deg) and nitward superior fatigue resistance, there was no significant difference in nitinol versus titanium construct fatigue resistance.
Prospective case series.
To evaluate the efficacy of anterior-only approach, for treatment of type C F4 (AO classification) traumatic subaxial cervical spine injuries.
Patients with type C F4 traumatic cervical injuries presenting to a tertiary center between June 2017 and July 2018 were included. Outcome measures included self-reported measures (Neck Disability Index, visual analogue scale, and return to work), radiological measures (local segmental angle, Ishihara curvature index, cervical lordosis angle, and step-off distance), fusion state, and neurological state according to American Spinal Injury Association (ASIA) Impairment Scale (AIS).
Twenty-one cases were operated by anterior approach with mean age 39.1 ± 13.8 years. The most common injury was at C4-5 (47.6%). Six out of 7 cases (85.7%) with preoperative neurological impairment showed late follow-up improvement by one or more grade in AIS. Complete anatomical reduction and imaging measures did not correlate significantly to the self-reporte neurological impairment and in patients with medical comorbidities or when a short operative time-compared with combined approach-is preferred.