Activity

  • Montgomery Bidstrup posted an update 6 days, 4 hours ago

    This work reports the incorporation of mixed-metal oxides (MMOs) such as Si/Ti and Si/Zr into latex paints in the form of thin coatings for permanent trapping of indoor formaldehyde. The formaldehyde removal performance of the surface coatings was evaluated in a lab-scale indoor air chamber, and the results were compared with those of powder analogues. Due to the pore blockage by the latex, the incorporation led to 6-30% reduction in adsorption capacity and 50-70% drop in the adsorption rate for MMO-latex paints relative to their powder MMO analogues. Under the operating conditions of concentration, temperature, and relative humidity, the Si/Zr-latex paints outperformed the Si/Ti counterparts. It was also observed that performance could decrease over excessive loading, for example, Si/Zr-latex paint with 15/1 Si/Zr weight ratio showed a 20% lower adsorption capacity than that of the Si/Zr-latex paint with 25/1 Si/Zr ratio at 5 ppmv, 25 °C, and 70% RH. While high temperature greatly reduced the adsorption rate of the MMO-latex paints, high humidity slightly promoted the rate of formaldehyde capture. In 10 L, flow-through chamber tests, 25Si/Zr-latex paint reduced 5 ppmv formaldehyde by up to 60% at 25 °C and 70% RH with an adsorption rate of 0.34 ppmv/h. Overall, this study highlights the potential of MMO-latex paints with optimized formation for the efficient abatement of indoor aldehydes.Increasing the local concentration of DNA-based probes is a convenient way to improve the sensitivity of biosensors. Instead of using organic solvents or ionic liquids that phase-separate with water based on hydrophobic interactions, we herein studied a classic aqueous two-phase system (ATPS) comprising polyethylene glycol (PEG) and dextran. Polymers of higher molecular weights and higher concentrations favored phase separation. DNA oligonucleotides are selectively enriched in the dextran-rich phase unless the pH was increased to 12. A higher volume ratio of PEG-to-dextran and a higher concentration of PEG also enrich more DNA probes in the dextran-rich phase. The partition efficiency of the T15 DNA was enriched around seven times in the dextran phase when the volume ratio of dextran and PEG reached 110. The detection of limit improved by 3.6-fold in a molecular beacon-based DNA detection system with the ATPS. The ATPS also increased the sensitivity for the detection of Hg2+ and adenosine triphosphate, although these target molecules alone distributed equally in the two phases. This work demonstrates a simple method using water soluble polymers to improve biosensors.Organic-inorganic hybrid halide perovskites (OIHPs) with inherent mixed ionic-electronic conduction ability have been proposed as promising candidates for memristors with unique optoelectronic characteristics. Despite the great achievements toward understanding the working mechanism and exploring their functionality as water-sensitive materials, the humidity effect on the resistive switching (RS) characteristics still remains to be studied. This study investigates the humidity effect on the RS characteristics of Au/CH3NH3PbI3/FTO memristor. GRL0617 research buy The memristor works well at moderate relative humidity (RH, less then 75%) and degrades rapidly at higher RH of 90%. An obvious decrease in low resistance states on increasing the RH level is observed, which could be attributed to water-induced reduction of the iodide migration barrier. Raman and X-ray diffraction analyses indicate that the migration barrier reduction possibly originated from the weakening of the Pb-I bond caused by the intercalation of water molecules into the crystal lattice. The humidity-sensitive RS characteristics of the memristor could extend the scope of OIHP application for sensing and security applications and also prompt researchers to pay attention to the humidity effect on memristor devices with OIHPs.Various clinical studies have shown that myocardial troponin T (cTnT) is highly correlated with acute myocardial infarction (AMI). A highly sensitive molecularly imprinted polymer (MIP) sensing electrode for the detection of cTnT in patients’ blood serum can enable cost-effective, rapid, and real-time testing for patients requiring intensive care. However, the existing MIP-based sensing electrode does not perform well for low-concentration detection of cTnT ( less then 0.2 ng/mL). In this study, a new type of sensing electrode, an anodic aluminum oxide molecularly imprinted (MIP/AAO) nanocomposite electrode is developed. By incorporating the AAO structure, i.e., one-dimensional (1D) pillars, through a semiconductor-compatible process, the new electrode exhibits a great performance improvement, higher sensitivity of 1.08 × 10-4 and 4.25 × 10-4 in the low ( less then 0.03 ng/mL)- and high-concentration regions, respectively, and a lower limit of detection (LoD) of 5.34 pg/mL. Because the composite electrode can maintain a linear characteristic in the measurement range of low-concentration cTnT, it can effectively improve the accuracy and reduce the error in cTnT measurement. In addition, the novel sensing electrode exhibits good reusability and specificity.Chemical oxygen demand (COD) is an important indicator of organic pollutants in water bodies. Most of the present testing methods have the disadvantages of having complicated steps, being time-consuming, and using toxic and hazardous substances. In this work, rapid potentiometric detection of chemical oxygen demand (COD) using a portable self-powered sensor chip was successfully developed. The indium tin oxide (ITO) electrode was etched by laser, and the photocatalytic materials TiO2/CuS and Pt were modified onto the photoanode and the cathode to prepare the sensor chip. Based on the principle of photocatalytic degradation, organic pollutants can be oxidized by TiO2/CuS, and the concentration will affect the generated voltage. The quantitative detection of COD in the range of 0.05-50 mg/L can be rapidly achieved within 5 min by a miniature device. Besides good portability and sensitivity, the proposed sensor also has the advantages of environmental friendliness and ease of use, which is an ideal choice for the on-site detection of water pollution.